						 4…20 mA output signal + HART 5 / HART 7 protocol (special version: 0…20 mA or 0…5 mA output signal + HART 5 protocol)
								
 Display with backlight
								
 Safety version SIL2/SIL3
								
 Intrinsic safety certificate ATEX, IECEx, FM, CSA(FM), INMETRO
								
 Explosion proof certificate ATEX, IECEx, FM, CSA(FM), INMETRO
								
 Programmable zero range, shift, characteristic and damping ratio with local panel keys
								
 Static pressure limit up to 700bar
								
 Accuracy 0,075% (0,05%, 0,04% on request)
								
 Marine certificate – DNV, BV
								
 Gold plated diaphragms
								
 Wetted parts material 316L/Hastelloy C276
								
 
						 4…20 mA output signal + HART protocol
								
 ATEX Intrinsic safety
								
 Static pressure limit up to 320 bar
								
 Accuracy 0.1%
								
 Wetted parts material 316L
								
 
						 4…20 mA output signal + HART protocol
								
 Intrinsic safety certificate (ATEX, IECEx)
								
 Static pressure limit up to 420 bar
								
 Accuracy 0,1%
								
 Wetted parts material Hastelloy C276
								
 Marine certificate DNV, BV
								
 
						 Digital communication protocol Modbus RTU
								
 Intrinsic safety and explosion proof certificates (ATEX, IECEx)
								
 Accuracy 0.1%
								
 Static pressure limit up to 413 bar
								
 Marine certificate DNV, BV
								
 
						 Overloads up to 420 bar total static pressure
								
 Accuracy 0,25%
								
 Any range from 0…16 mbar up to 0…25 bar
								
 Intrinsic safety certificate (ATEX, IECEx)
								
 Marine certificate – DNV, BV
								
 
						 Accuracy 0.4%
								
 Measuring ranges: 0 ÷ 1, 0 ÷ 2.5, 0 ÷ 4 bar; 0 ÷ 6, 0 ÷ 10 bar; 0 ÷ 16, 0 ÷ 25 bar
								
 Output signal 4 ÷ 20 mA or 0 ÷ 10 V
								
 Process connection: M20x1,5, 1/4”NPTF
								
 
						Smart or analog differential pressure transmitters with diaphragm seals for level measurement to pressure tank with gas-filled negative pressure line are recommended transmitters with diaphragm seal mounted on "+" side to pressure tank with liquid-filled negative line are recommended transmitters with diaphragm seal mounted on "-" side and converted output signal.
More information -> 
						 4...20 mA output signal + HART 5 / HART 7 protocol
								
 Accuracy 0,1%
								
 Safety version SIL2/SIL3
								
 Intrinsic safety certificate ATEX, IECEx, FM, CSA (FM), INMETRO
								
 Explosion proof certificate ATEX, IECEx, FM, CSA (FM), INMETRO
								
 Fully welded sensor guarantees tightness of oil system for many years
								
 Ability to configure measuring range locally
								
 
						 Measurement of differential pressure based on two absolute pressure transmitters
								
 Modular construction with posibility of replacing of each module of the measuring system
								
 Output signal 4 ÷ 20 mA + HART
								
 Accuracy 0,1%